Series PVHRU

PVHRU Max Quiet Heat Recovery Units

Benefits

  • Low profile from 300mm deep.
  • Up to 90% Heat Recovery efficiency.
  • Outperforms ErP 2018.
  • Heating Coil options. LPHW or electric.
  • Cooling coil options chilled water or DX.
  • Heat pump coil options.
  • TM52 compliant.
  • On board controls available.
  • Filtration to F7.
  • Summer by pass facility.
  • High sound reduction casework tested to BS EN ISO 10140-2 (2010) UKAS certified.
  • High performance backward curved centrifugal fans with low specific fan power.
  • Meets BB101 and BB93 Feb 2015.
  • Bottom access.
Download brochure Download fact sheet
 

Environmentaly friendly systems.

Provides good indoor air quality.

Recovery reduces energy costs.

High efficiency heat pump technology.

Hydrocarbon benign refrigerant available.

Product Development...

The Company is continually updating its products to comply with changing energy saving technologies, so the introduction of the PVHRU Range of low profile heat reclaim air handling units is based on changes in Fan technology, with the introduction of EC backward curved direct driven plug fans, with 0<10V speed control. Multi fan wall arrangements have been adopted to give higher performance with lower energy consumption. Our team of research professionals are committed to developing products with sustainable energy solutions to meet today’s demands for reducing ventilation energy consumption.

Compliance...

The Packaged Void Heat Reclaim Unit range has been developed to meet the specific fan power requirements of Building Regulations, BS EN 1886 Class B Construction Standards and Ecodirective ErP 2018.

Acoustic Performance...

Extensive acoustic testing of casework construction has been carried out at both the companies testing facilities, and Salford University Acoustic Testing Laboratory. Acoustic tests were carried out on eleven double skin composite panel/frame systems, eight different triple and quadruple skin composite panel/frame systems, to BS. EN ISO10140-2 (2010) which have all been certified as UKAS accredited.

BB93 feb 2015 acoustic reports noise reduction schools (PDF)

Air Handling Units Acoustic Insulation Performance Tests (Online Version)

Sound Advice for Ventilation Plant in Schools (PDF)

Sound Advice for Ventilation Plant in Schools (Online Version)

Enquire about our heating, ventilating and air conditioning systems

We supply and manufacture aircraft air handling, ECE ltd, barkell envirotec, VES, nuaire, flaktwoods, air source ventilation swegon, air handling systems, air handling unit manufacturers, AHU manufacturers, school air handling unit manufacturers, heat recovery air handling units, heat pump air handling units, low profile air handling units, low noise air handling units health care air handling units, packaged air handling units, modular air units, central station air handling units.

Classvent quiet classvent with reduced noise breakout. low noise breakout school classroom ahu quiet school classroom ahu classroom unit to meet the new BB93 2015 noise tested classroom air handling unit Envirofresh quiet low noise tested packaged air handling unit heat pump unit heat pump AHU with low noise breakout quiet AHU heat pump unit noise tested air handling unit heat pump Sound Advice For Ventilation Plant In Schools